Learn R Programming

PowerUpR (version 0.1.3)

mdes.bira4r1: Model 2.5: MDES Calculator for 4-Level Random Effects Blocked Individual Random Assignment Design, Individuals Randomized within Blocks

Description

mdes.bira4r1 calculates minimum detectable effect size (MDES) for designs with 4-levels where level 1 units are randomly assigned to treatment and control groups within level 2 units (random blocks).

Usage

mdes.bira4r1(power=.80, alpha=.05, two.tail=TRUE,
       rho2, rho3, rho4, omega2, omega3, omega4,
       P=.50, R12=0, RT22=0, RT32=0, RT42=0, g4=0,
       n, J, K, L, ...)

Arguments

power
statistical power (1 - type II error).
alpha
probability of type I error.
two.tail
logical; TRUE for two-tailed hypothesis testing, FALSE for one-tailed hypothesis testing.
rho2
proportion of variance in the outcome explained by level 2 units.
rho3
proportion of variance in the outcome explained by level 3 units.
rho4
proportion of variance in the outcome explained by level 4 units.
omega2
treatment effect heterogeneity as ratio of treatment effect variance among level 2 units to the residual variance at level 2.
omega3
treatment effect heterogeneity as ratio of treatment effect variance among level 3 units to the residual variance at level 3.
omega4
treatment effect heterogeneity as ratio of treatment effect variance among level 4 units to the residual variance at level 4.
P
average proportion of level 1 units randomly assigned to treatment within level 2 units.
g4
number of covariates at level 4.
R12
proportion of level 1 variance in the outcome explained by level 1 covariates.
RT22
proportion of treatment effect variance among level 2 units explained by level 2 covariates.
RT32
proportion of treatment effect variance among level 3 units explained by level 3 covariates.
RT42
proportion of treatment effect variance among level 4 units explained by level 4 covariates.
n
harmonic mean of level 1 units across level 2 units (or simple average).
J
harmonic mean of level 2 units across level 3 units (or simple average).
K
harmonic mean of level 3 units across level 4 units (or simple average).
L
number of level 4 units.
...
to handle extra parameters passed from other functions, do not define any additional parameters.

Value

fun
function name.
par
list of parameters used in MDES calculation.
df
degrees of freedom
M
multiplier for MDES calcuation given degrees of freedom, \(\alpha\) and \(\beta\) (1-power).
mdes
minimum detectable effect size and 95% lower and upper confidence limits.

Details

MDES formula and further definition of design parameters can be found in Dong & Maynard (2013).

References

Dong, N., & Maynard, R. A. (2013). PowerUp!: A Tool for Calculating Minum Detectable Effect Sizes and Minimum Required Sample Sizes for Experimental and Quasi-Experimental Design Studies,Journal of Research on Educational Effectiveness, 6(1), 24-6.

See Also

power.bira4r1, mrss.bira4r1, optimal.bira4r1

Examples

Run this code
## Not run: ------------------------------------
# 
#   mdes.bira4r1(rho4=.05, rho3=.15, rho2=.15,
#               omega4=.50, omega3=.50, omega2=.50,
#               n=10, J=4, L=27, K=4)
#   
## ---------------------------------------------

Run the code above in your browser using DataLab