Learn R Programming

EnvStats (version 2.1.0)

plotPredIntLnormAltTestPowerCurve: Power Curves for Sampling Design for Test Based on Prediction Interval for Lognormal Distribution

Description

Plot power vs. $\theta_1/\theta_2$ (ratio of means) for a sampling design for a test based on a prediction interval for a lognormal distribution.

Usage

plotPredIntLnormAltTestPowerCurve(n = 8, df = n - 1, n.geomean = 1, k = 1, 
    cv = 1, range.ratio.of.means = c(1, 5), pi.type = "upper", conf.level = 0.95, 
    plot.it = TRUE, add = FALSE, n.points = 20, plot.col = "black", 
    plot.lwd = 3 * par("cex"), plot.lty = 1, digits = .Options$digits, ..., 
    main = NULL, xlab = NULL, ylab = NULL, type = "l")

Arguments

n
positive integer greater than 2 indicating the sample size upon which the prediction interval is based. The default is value is n=8.
df
positive integer indicating the degrees of freedom associated with the sample size. The default value is df=n-1.
n.geomean
positive integer specifying the sample size associated with the future geometric mean(s). The default value is n.geomean=1 (i.e., individual observations). Note that all future geometric means must be based on the same sample size.
k
positive integer specifying the number of future observations that the prediction interval should contain with confidence level conf.level. The default value is k=1.
cv
positive value specifying the coefficient of variation for both the population that was sampled to construct the prediction interval and the population that will be sampled to produce the future observations. The default value is
range.ratio.of.means
numeric vector of length 2 indicating the range of the x-variable to use for the plot. The default value is range.ratio.of.means=c(1,5).
pi.type
character string indicating what kind of prediction interval to compute. The possible values are pi.type="upper" (the default), and pi.type="lower".
conf.level
numeric scalar between 0 and 1 indicating the confidence level of the prediction interval. The default value is conf.level=0.95.
plot.it
a logical scalar indicating whether to create a plot or add to the existing plot (see explanation of the argument add below) on the current graphics device. If plot.it=FALSE, no plot is produced, but a list of (x,y) valu
add
a logical scalar indicating whether to add the design plot to the existing plot (add=TRUE), or to create a plot from scratch (add=FALSE). The default value is add=FALSE. This argument is ignored if pl
n.points
a numeric scalar specifying how many (x,y) pairs to use to produce the plot. There are n.points x-values evenly spaced between range.x.var[1] and range.x.var[2]. The default value is n.points=100.
plot.col
a numeric scalar or character string determining the color of the plotted line or points. The default value is plot.col="black". See the entry for col in the help file for par
plot.lwd
a numeric scalar determining the width of the plotted line. The default value is 3*par("cex"). See the entry for lwd in the help file for par for more information.
plot.lty
a numeric scalar determining the line type of the plotted line. The default value is plot.lty=1. See the entry for lty in the help file for par for more information.
digits
a scalar indicating how many significant digits to print out on the plot. The default value is the current setting of options("digits").
main, xlab, ylab, type, ...
additional graphical parameters (see par).

Value

  • plotPredIntLnormAltTestPowerCurve invisibly returns a list with components:
  • x.varx-coordinates of points that have been or would have been plotted.
  • y.vary-coordinates of points that have been or would have been plotted.

Details

See the help file for predIntLnormAltTestPower for information on how to compute the power of a hypothesis test for the ratio of two means of lognormal distributions based on a prediction interval for a lognormal distribution.

References

See the help files for predIntNormTestPower and tTestLnormAltPower.

See Also

predIntLnormAltTestPower, predIntLnormAlt, predIntNorm, predIntNormK, plotPredIntNormTestPowerCurve, predIntLnormAltSimultaneous, predIntLnormAltSimultaneousTestPower, Prediction Intervals, LognormalAlt.

Examples

Run this code
# Plot power vs. ratio of means for k=1 future observation for 
  # various sample sizes using a 5% significance level and assuming cv=1.

  dev.new()
  plotPredIntLnormAltTestPowerCurve(n = 8, k = 1, 
    range.ratio.of.means=c(1, 10), ylim = c(0, 1), main = "") 

  plotPredIntLnormAltTestPowerCurve(n = 16, k = 1, 
    range.ratio.of.means = c(1, 10), add = TRUE, plot.col = "red") 

  plotPredIntLnormAltTestPowerCurve(n = 32, k = 1, 
    range.ratio.of.means=c(1, 10), add = TRUE, plot.col = "blue") 

  legend("topleft", c("n=32", "n=16", "n=8"), lty = 1, lwd = 3 * par("cex"), 
    col = c("blue", "red", "black"), bty = "n")

  title(main = paste("Power vs. Ratio of Means for Upper Prediction Interval", 
    "with k=1, Confidence=95%, and Various Sample Sizes", sep=""))
  mtext("Assuming a Lognormal Distribution with CV = 1", line = 0)

  #==========

  # Pages 6-16 to 6-17 of USEPA (2009) present EPA Reference Power Curves (ERPC)
  # for groundwater monitoring:
  #
  # "Since effect sizes discussed in the next section often cannot or have not been 
  # quantified, the Unified Guidance recommends using the ERPC as a suitable basis 
  # of comparison for proposed testing procedures.  Each reference power curve 
  # corresponds to one of three typical yearly statistical evaluation schedules - 
  # quarterly, semi-annual, or annual - and represents the cumulative power 
  # achievable during a single year at one well-constituent pair by a 99  # (normal) prediction limit based on n = 10 background measurements and one new 
  # measurement from the compliance well.
  #
  # Here we will create a variation of Figure 6-3 on page 6-17 based on 
  # using a lognormal distribution and plotting power versus ratio of the 
  # means assuming cv=1.

  dev.new()
  plotPredIntLnormAltTestPowerCurve(n = 10, k = 1, cv = 1, conf.level = 0.99, 
    range.ratio.of.means = c(1, 10), ylim = c(0, 1), main="")

  plotPredIntLnormAltTestPowerCurve(n = 10, k = 2, cv = 1, conf.level = 0.99, 
    range.ratio.of.means = c(1, 10), add = TRUE, plot.col = "red", plot.lty = 2)

  plotPredIntLnormAltTestPowerCurve(n = 10, k = 4, cv = 1, conf.level = 0.99, 
    range.ratio.of.means = c(1, 10), add = TRUE, plot.col = "blue", plot.lty = 3)

  legend("topleft", c("Quarterly", "Semi-Annual", "Annual"), lty = 3:1, 
    lwd = 3 * par("cex"), col = c("blue", "red", "black"), bty = "n") 

  title(main = paste("Power vs. Ratio of Means for Upper Prediction Interval with",
    "n=10, Confidence=99%, and Various Sampling Frequencies", sep="\n"))
  mtext("Assuming a Lognormal Distribution with CV = 1", line = 0)

  #==========

  # Clean up
  #---------
  graphics.off()

Run the code above in your browser using DataLab