Type of hydro file, it can be "waterValues", "reservoir", "maxpower", "inflowPattern" or "creditmodulations".
data
The data must have specific dimension depending on the type of file :
waterValues: a 365x101 numeric matrix:
marginal values for the stored energy based on date (365 days)
and on the reservoir level (101 round percentage values ranging from
0% to 100%). OR a 3-column matrix with 365x101 rows. In this latter case the 3 columns must
be 'date', 'level' and 'value' (in this order), and the rows must be sorted by:
ascending day, ascending level.
reservoir: a 365x3 numeric matrix. The columns contains respectively the levels min, avg and max.
maxpower: a 365x4 numeric matrix.
inflowPattern: a 365x1 numeric matrix.
creditmodulations: a 2x101 numeric matrix.
overwrite
Logical. Overwrite the values if a file already exists.
opts
List of simulation parameters returned by the function
antaresRead::setSimulationPath().
Warning
For an Antares version >= 860, control of data consistency between mingen.txt and maxpower_<area>.txt can be executed.
This control depends on the values you find in hydro.ini file.