Retrieves the specified alarms. You can filter the results by specifying a a prefix for the alarm name, the alarm state, or a prefix for any action.
cloudwatch_describe_alarms(AlarmNames, AlarmNamePrefix, AlarmTypes,
ChildrenOfAlarmName, ParentsOfAlarmName, StateValue, ActionPrefix,
MaxRecords, NextToken)
The names of the alarms to retrieve information about.
An alarm name prefix. If you specify this parameter, you receive information about all alarms that have names that start with this prefix.
If this parameter is specified, you cannot specify AlarmNames
.
Use this parameter to specify whether you want the operation to return metric alarms or composite alarms. If you omit this parameter, only metric alarms are returned.
If you use this parameter and specify the name of a composite alarm, the
operation returns information about the \"children\" alarms of the alarm
you specify. These are the metric alarms and composite alarms referenced
in the AlarmRule
field of the composite alarm that you specify in
ChildrenOfAlarmName
. Information about the composite alarm that you
name in ChildrenOfAlarmName
is not returned.
If you specify ChildrenOfAlarmName
, you cannot specify any other
parameters in the request except for MaxRecords
and NextToken
. If
you do so, you will receive a validation error.
Only the Alarm Name
, ARN
, StateValue
(OK/ALARM/INSUFFICIENT\_DATA), and StateUpdatedTimestamp
information
are returned by this operation when you use this parameter. To get
complete information about these alarms, perform another
DescribeAlarms
operation and specify the parent alarm names in the
AlarmNames
parameter.
If you use this parameter and specify the name of a metric or composite
alarm, the operation returns information about the \"parent\" alarms of
the alarm you specify. These are the composite alarms that have
AlarmRule
parameters that reference the alarm named in
ParentsOfAlarmName
. Information about the alarm that you specify in
ParentsOfAlarmName
is not returned.
If you specify ParentsOfAlarmName
, you cannot specify any other
parameters in the request except for MaxRecords
and NextToken
. If
you do so, you will receive a validation error.
Only the Alarm Name and ARN are returned by this operation when you use
this parameter. To get complete information about these alarms, perform
another DescribeAlarms
operation and specify the parent alarm names in
the AlarmNames
parameter.
Specify this parameter to receive information only about alarms that are currently in the state that you specify.
Use this parameter to filter the results of the operation to only those alarms that use a certain alarm action. For example, you could specify the ARN of an SNS topic to find all alarms that send notifications to that topic.
The maximum number of alarm descriptions to retrieve.
The token returned by a previous call to indicate that there is more data available.
svc$describe_alarms( AlarmNames = list( "string" ), AlarmNamePrefix = "string", AlarmTypes = list( "CompositeAlarm"|"MetricAlarm" ), ChildrenOfAlarmName = "string", ParentsOfAlarmName = "string", StateValue = "OK"|"ALARM"|"INSUFFICIENT_DATA", ActionPrefix = "string", MaxRecords = 123, NextToken = "string" )